Cast Iron boiler repair

Hello, I have a very old cast iron boiler. Gas fired. We have a internal leak. It starts up and runs, but after a while, water is leaking onto the flame sensor, the pilot goes out. I have to go and...

View Article


Image may be NSFW.
Clik here to view.

Navien CH240 - No Heat in radiators but has domestic hot water

I have a six year old Navien CH240 combi boiler. Worked fine for the last six winters. Only thing I had to change besides cleaning filters was expansion tank so far. However when turned up thermostat...

View Article


Old wall heater gas valve replacement recommendation

Looking for a Montgomery Wards wall heater, SFB 50314 07X, replacement gas valve, Essex TF-5, recommendation

View Article

Steam boiler won't start (Weil McLain PEG50)

Please help with identifying the root cause of my heating problem Weil McLain PEG50 (2017), Hunter thermostat. Just heat, no HVAC. I disconnected thermostat for about a month due to construction. Today...

View Article

Taco Zone Valve box noise

I have a Taco ZVC403 zone valve control box. I have 3 zones each having their own thermostat. When a zone calls for heat there is a “LOUD” buzzing noise and I believe it is coming from the zone valve...

View Article


Weil Mclain Ultra 80 NG - Series 2 non start

HI, My Weil Mclain Ultra 80 NG - Series 2 boiler developed an issue after about 1 month of this heating season. A hard lockout with an E16 error code was displayed. The troubleshooting guide suggested...

View Article

2 Existing hydrotherm to 1 Superhot AAA840 (Venting) (Canadian Code)

Hey everybody, We have a couple of apartment buildings that we are going to be doing some retrofit work to. We're going to be installing 1 Superhot AAA-840 Boiler (1 - 14" Flue Collar) in lieu of 2...

View Article

TempStar 90 plus furnace momentary shut down and restart in mid operation.

I have a Tempstar T9UHX100L201A 90 % furnace. I have noticed that mid operation the unit shuts down and quickly restarts. I have noticed it also happens during the cooling cycle and Heating cycle....

View Article


Smoke test

Hello, Can you perform a smoke test on a boiler that is not running? 2 plumbers are telling me that my chimney needs to be relined and it failed the smoke test...yet boiler not running. Just wanted to...

View Article


Image may be NSFW.
Clik here to view.

Carlin G3B Intermittent Flame Fix

If your Carlin G3B Burner Flames on and then Flames off, or has an Intermittent Flame On and Flame Off, you need to check the blower cage wheel that brings the Airflow or Oxygen into the unit, it can...

View Article

CH- Anti-Cycling on HTP

Tryinng to cut down some of my cycling of my htp uft 80. I have adjusted my odr, to the best of my ability, i have it running almost constant, but still have some turn offs. There is an anti cycle...

View Article

Bad propane

How many of you guys have had issues firing a boiler on propane? I was in a veisemann class and the instructor asked how much trouble we’ve had with propane. The class full of seasoned heating guys had...

View Article

Image may be NSFW.
Clik here to view.

Navien NCB 240 flame loss (error 12)

Hi all, A couple times a day, and especially every early morning, I get Error 012 (flame loss) at my Navien NCB 240. I have to reset the boiler to make it work again. I have called the installer...

View Article


Correct size & Brand Boiler

I need to replace my old gas boiler. I live in Massachusetts. I have gotten some quotes. The 3 brands suggested are Viessmann, Lochinvar and Weil-McClain. Only one company has done a heat loss...

View Article

Image may be NSFW.
Clik here to view.

Trane XR90 condensate fitting?

Trane XR90 was installed with no condensate neutralizer. I am adding one, however the PVC drain tubing outside the furnace is installed tight to a grey fitting, which will probably have to be replaced...

View Article


Tankless Boiler Makeup Water

I understand it is correct to fill the system a the point of no pressure where the expansion tank is installed on the system...why is there an internal fill valve built into Navien's Combi Boiler if...

View Article

30psi and flowing water sound in pipe

Hello there, I have this 140k Weil McClain boiler for 2nd floor only, abt 1000 sq ft. I cant sleep at night because its got problems. 1) Is the boiler oversize or the water too low in the boiler? I see...

View Article


Navien tankless propane combination boiler water heater

a couple of times in the last week we’ve noticed the outside exhaust pipe cover/grate (the one I’m assuming keeps pests out) on the outside boiler exhaust has blown out and landed all the way in the...

View Article

Safe to close valve for incoming water on Hydronic boiler?

Hello. I have a two zone, two TACO pump, hydronic gas boiler system with expansion tank. The boiler is probably over 25 years old but I can't afford to replace it this year. The red zone is 30 PSI for...

View Article

Image may be NSFW.
Clik here to view.

Buderus GB142 ... multiple corrosion issues.

A noob here, thanks for all the terrific advice. Hoping to get your views on the following. Pics attached. I've got a new-to-me, approximately 10 year old, natural gas fired GB142 w/ indirect Buderus...

View Article