Munchkin Versions and control stategies/blocked vent control/ vision

I have a Munchkin in service in a staged setup that replaced a heatmaker. i make it out to be a prerevision munchkin that was upgraded from the honeywell control to the 925 so it is now Rev 1 although...

View Article


Replace prorated warranteed(40%) cast iron heat exchanger or replace 18 yr....

We have a n 18 yr. old burnham series three. The heat echanger is non useable. Do I go with a new boiler or all the stressors of getting the exchanger replaced. Looking at a lennox gwb3-e replacement....

View Article


Need help deciding gas condensing boiler

What do you recommend between Buderus GB142-24, Greenstar ZBR21-3, HTP EFT-80, and Triangle Tube PA80? Thanks.

View Article

Million dollar question what size modcon gas boiler

Hi everyone I'm a homeowner in the market to replace my old cast iron boiler. I'm looking at going to a 95+ afue modcon boiler to take advantage of the rebates offered by massave. I live in Seekonk...

View Article

Boiler water pressure

My boiler pressure is always around 30-35 PSI. I have bled water off but it recovers back to 30-35 within seconds. Help,please.

View Article


Buderus GB 142 ignition issue (6A)

New customer has a GB142 with 6A code. Previous company replaced gas valve and venturi. If I put my hand over venturi, the unit will light. Hand off.....and no ignition. Gas pressures are all within...

View Article

No heat, Taco ZVC404 only power light on

The heat was not coming on per my wife. Propane Crown Boiler (18 years old), Taco ZVC404(4 zone but I only use two, two story cape house) 1st floor thermostat calling for heat, but the only light on is...

View Article

New Lochinvar install. Primary Loop Delta T question

Just wanted to thank everyone here for all the great information posted on this site. I've been loitering around the site while installing a new boiler and the info I've found here has been invaluable....

View Article


ESSEX gas valve (Call out for Tim)

Does anyone have any info on an Essex SX 243 gas valve; 243110801-135; 24 volt .2 amp Class I 6.4 set at 3.5 WC; cust # EF530c(?) Z 301. It is on a Bryant/Dunkirk 246B-6, 525,000 BTUH input---1979??...

View Article


No power to the thermostat

I have a steam and gas boiler and there is no power to the thermostat. The thermostat is wired, mercury, round Honeywell. I opened up the thermostat and used a multimeter to check for voltage on the...

View Article

Concentric Vent modification.

Wondering how I can achieve greater height off roof with my concentric vent for my Modcon boiler. its currently 14in from roof to bottom of rain cap where intake air goes in. My boiler manual states I...

View Article

Old Warm Morning = cold heart

So my very old Warm Morning gas heater has been having intermittent pre ignition / flashback problems. I have cleaned the cast iron burner several times. Checked the orifice, it’s clean. Adjusted...

View Article

Boiler stops running after a few hours

It is a gas steam boiler with a wired-in thermostat. Everyday, it always runs first time I turn it on. But it stops running after about 2 hours. When it runs, I use a multimeter to check and find...

View Article


Smart Thermostats for Viessmann Vitopend 100

Hello, I am looking for recommendations for a smart Internet-enabled thermostat to remotely control my Viessmann Vitopend 100. My research shows that tado thermostat is compatible with my heater. But...

View Article

Main Vent Help

Hello, I've been fidgeting with my steam heat system since I bought my house almost 3 years ago. I recently decided to get a repair man to finish off the rest of the job but after his initial visit...

View Article


Does Buffer Tank with Modcon Make a Precise TDR Match Less Critical?

(HO here) It seems to me that with a mod con and buffer tank, firing cycles would be longer and the system could sip from the buffer to meet the heating load rather than from a highly modulated burner,...

View Article

Image may be NSFW.
Clik here to view.

How to bleed - water feed on return side.

Hi there. I have a three zone radiant heating system with 3 circulators. The water feed is piped directly to the return line on one of the zones. If I try to isolate any of the other zones - how do I...

View Article


For hot water heating system spontaneous boiler pressure rise and opening of PRV

The Burnham boiler for my forced hot water heating system has been making a lot of noise. So I decided to drain the boiler and refill it to the manufacturer’s spec of 12 psi with the water cool. About...

View Article

Noritz Combi Nightmare

Hi. I am struggling with a new Noritz CB 180 installation. We have a brand new install - less than a month old. Its a CB 180 in a condo serving both domestic hot water and a First Co Airhandler Hot...

View Article

Buderus GB142-60 AM10 Setpoint

New/Used install of boiler unit DHW off, Space heating temp dial set to 125 degrees. AM10 module is calling for a flow temp of 120, boiler maintains a 100 degree temp with a Delta T of 25-30 degrees....

View Article