LP Gas pressures chaging????
Got a stumper, we have a one year old Bosch KBR Lp boiler, these boilers have been rock solid. This job we've been back 3 times, each time the o2/co2 numbers are different from where we left it. Any...
View ArticleBosch Greenstar Combi 151 not able to keep up
I got a bosch combi unit installed last year. I am having some trouble with it. It is not able to keep up on a cold day. I am wondering if it is related to any of the settings not set correctly. I...
View ArticleBurnham boiler making loud knocking sounds
My home’s boiler has recently started making a lot of noise. It sounds like pebbles are crashing around inside when the boiler is running. When the boiler turns off (but the circulator pump is still...
View Articlegoodman gas furnace not lighting
Hey guys, had a goodman gms80403an-12040013772 furnace. tech support said to replace board and we did. whats going on is inducer goes, glows,and hear gas valve click a bit and flutters, have good gas...
View ArticleBoth Relief Valves spitting out water, too much pressure in sytem.
I had a part on my pipes that was leaking water so I had plumber#1 come in to take care of this.He told me that the way my boiler room was setup was backwards:1. Expansion tank on boiler was no good...
View ArticleClow gas steam radiator for sale
I have an antique Clow gas steam radiator for sale. It does need some minor work to get working again.
View ArticleLP GAs Pressure - Is it a potential problem
I have a Teledyne LAARS JVT-100c 70,000BTU hot water heat on Propane at an altitude of 7.300 ft. in Colorado. Although 25 years old it has worked well but has several irritating issues that have been...
View ArticleSuper store SSU45
Just installed it with W/M Go-3. Circ not calling aqua stat set at lowest setting installed a swet check 3/4 but still getting 160 degree DHW from it and can't cool it down. The supply pipe is hot but...
View ArticleHelp with new boiler purchase please
Hello Everyone,I apologize ahead of time as im totally new to boilers. I grew up down south and moved to Long Island and bought a house. The boiler in there now is from 1969 leaks and im sure will die...
View ArticleRheem Classic 90 Plus furnace - Pilot light acting up
Hello! I have a Rheem Classic 90 Plus in my condo, circa 1998. I moved in about a year ago, and have had no problems with the furnace until now. I was hoping I could get some insight on the issue I'm...
View ArticleYork Warm air furnace problems
Installed a York upflow furnace last year with AC coil. Furnace shutting down blowing cold air then on again normal then cold air. 4 flash error code says flow issue. I changed limit and temp control...
View ArticleVeissmann Vitoden 200 B2HB 45 Boiler
I have an assignment for school, that is asking me to find the best place to get info about boilers and AC units. So i'm looking for any info that will help.
View ArticleHot gas supply line
I just moved into a new home. It has a natural gas supplied ventless 30,000 BTU wall heater. It is in the basement which is unfinished, but does have a 4'x8 piece of sheetrock behind it. The black pipe...
View ArticleConversion burner exhaust pipe has 3/8 inch hole.
Furnace Gas Conversion burner 6 inch galvanized exhaust pipe has almost 3/8 inch hole poked in it for 40 years.We're not dead yet. What is the best way to easily fix this?3/8 inch bolt won't fit but...
View ArticleGas pipe sizing--summation method Q
I need to add a gas line for a cooktop to my existing natural gas piping. I have been stifled in this because the standard sizing charts indicate that my 3/4" supply is too small right off the bat....
View ArticleCarrier
Carrier 90 with plugged secondary. Don't need a $1300 CA, your nose usually can tell you!
View ArticleLeaking fireplace globe valve
I have a globe valve on the floor by my fireplace which operates with a key. When closed, it seals completely. When open however, it leaks around the shaft. I suspect that the packing has deteriorated...
View ArticleWeil McLain Ultra 2: DHW always on
I have a Weil McLain Ultra 2 for radiant and DHW. It's finally winter today, and the house didn't stay warm. When I looked at the boiler, it showed E 02 error code : "5 ignition attempts failed". I...
View ArticleRheem furnace RGAA-08EC
Trying to pin point problem on this older furnace..If the pilot light is not lit and I adjust the temperature up above room temp at thermostat the igniter lights the pilot and then burners light blower...
View ArticleNoritz Combi Nightmare
Hi.I am struggling with a new Noritz CB 180 installation.We have a brand new install - less than a month old. Its a CB 180 in a condo serving both domestic hot water and a First Co Airhandler Hot Water...
View Article