2 month old circulator not silent anymore
15-58 3 speed circulator that ran almost silent for about five or six weeks is now rattling constantly when running no matter what speed it's set on. This was installed new in Oct along with a boiler....
View ArticleWhat do you think of the Lochinvar Knight KHN155 gas-fired boiler?
Hi folks -- My family just moved into a new 4-bedroom, 2-story colonial near Boston and need to replace our boiler. In order to qualify for the MassSave purchase loan program and $3,000 boiler...
View ArticleSteam air on eyes
Hey, I happen to get some hot steam air from apartment radiator on my eyes. My eyes began to hurt and it feels like a burning sensation. Should I worry or is this just temporary. Is the air from my...
View ArticleYork Warm air furnace problems
Installed a York upflow furnace last year with AC coil. Furnace shutting down blowing cold air then on again normal then cold air. 4 flash error code says flow issue. I changed limit and temp control...
View ArticleOld, doesn't mean dead.
We are an 50 year old waterfront motel with wall mounted gas furnaces. The one I am having trouble with is a Royal (Chattanooga TN) Model 07820AWN. This unit was fully functional early December. We...
View ArticleCondensate dripping from exhaust vent connection
I have a Burnham Alpine boiler, installed maybe 6 years ago, and noticed condensate dripping from the connection between the CPVC exhaust vent pipe and the stainless connector at the back of the...
View ArticleConventional Hydronic Boiler with multi-zones
I am retrofitting multiple zones into my current system and I was thinking that the boiler could be shocked with cold water from 1 zone with hot water on already and another zone of cold water being...
View ArticleMouse troubles
I've run into a mouse nest several times in the intake air PVC and always been able to clear them with a soot vac. Today I've found a very long run of 3" piping that's clogged and the soot vac hose is...
View ArticleGas heating - Gas Valve or Circuit Board?
Hello all,I've been reading the forums here and had two folks with the same issue as me, but they did not answer back with the result. What a bummer. I could tell that you guys were disappointed. I...
View ArticleThe right size boiler Navien 60,000 or 80,000
I am trying to figure out what boiler will work from my house better. I live in Worcester Massachusetts ZIP Code 01605 in a ranch style house 1076 ft.² built in 1947 with one bathroom. Recently had...
View Articlef09 error code for munchkin boiler
I am installing a used munchkin boiler. I keep getting the f09 error code. I have good spark and gas to the furnace. How do I know if the gas valve is working correctly or is defective?
View ArticleEconomite Conversion Burner Model E20A
Does anyone have an Economite E20A conversion burner manual? It has a tag on it saying it was installed in 1980. Can you help me, the motor is starting to squeak.
View ArticleThe right boiler Best of the Best
Had a plumber recommend the Lochinvar knight boiler KHN085. But I was also looking at Navien Combi or Rinnai Combi and a Bosch Greenstar. I know there are a lot of brands out there. But out of these or...
View ArticleRay-tec radiant heater
I have a Ray-tec radiant heater and when I turn it on theres flame coming out of two cells of the heater
View ArticleTaco SR504 Indirect DHW wiring
I want to replace 3-24v relays that power 3 Taco circ. with the SR504. My question is how do I energize a relay mounted on the Weil Mclain board. The WM 24v circut is used to power the relay through...
View ArticleWhat boiler would you put in your house
I was still wondering what boilers are the best of the best. So the best way to look at it what would you put in your house? Under 85,000 BTUs Example Lochinvar KHN085 Reason: It has a turn down 10:0...
View ArticleL7148F1075
I'm having a heck of time finding a cross to this obsolete aquastat. I don't need one right away but a colleague of mine needs one right now. I also have quite a few Buderus boilers out there that use...
View ArticleMunchkin F18 error after new parts
10 year old Munchkin 140 boiler. Maintained/cleaned yearly. Recently have been getting F18 error "gas valve failure" Replaced gas valve low voltage wiring harness also replaced the gas valve with a...
View ArticleWaters not getting hot
Does anyone know about this issue can't figure out what's wrong with my water heater
View ArticleBoiler Losing Heat, Bad L8148E Aquastat?
I have a mercury-free CT87K that will call for heat when temperature is set 10degrees ABOVE room temperature. (I plan on replacing the newly installed Honeywell with a White Rodgers M80, which seems to...
View Article