hot water boiler
I have a gas fired hot water boiler, i set my thermostat at 68 , next moring the house is 83, i took the tt wires off the beckett control, and the next morning same thing, what might be the problem,...
View ArticleCommercial Hydronics Future?
I know air-to-water, geo and solar are some options when consumers are looking to reduce carbon footprint. More companies are bringing out products and a lot are lower output in both the temperature...
View ArticleWeil Mclain ultra 155 series 2 Digital display dead
I have a Weil Mclain ultra 155 series 2. I have to often reset it when it heats domestic hot water as it goes too high. Today it was flashing code E 05. I hit the reset and the entire digital display...
View ArticleVery strange boiler problem
Okay so I noticed a couple of days ago that my gas boiler was acting strange. I turned on the heat on my thermostat and my radiators were heating up. But after about 20 mintues the radiators weren't...
View ArticleAll-electric replacement for Munchkin?
My first time posting here. We have a Munchkin MU-199M that was installed in 2007 and may need to be replaced. I’d like to avoid another gas boiler if possible because my plumber (who’s serviced the...
View ArticleAmerican Standard control board flashing 3x
It's a large, old, poorly insulated house, heated by two American Standard 105,000 BTU 80% efficient approx 10-year old furnaces. They are twinned together and I refer to them as F1 and F2. Several...
View ArticleCracked Heat Exchanger?
I have a very long thread on here with all of the issues I’ve had over the last few months, but thought I’d repost with a more direct question for those not inclined to wade through 6 months of...
View ArticleBOSCH T9800SE 160K BTU having Heating Problem Water Flow Rate shows 0.3gpm No...
Hi there, I need help from BOSCH Experience exports those who have knowledge about this BOSCH. We have BOSCH T9800SE 160K BTU Machine, and we have Heating problem from last full Winter 2022-2023. When...
View Article20 Year old Munchkin, efficient house, looking for next steps
This is a 20 year old house, I use 400 therms of natural gas to heat it for the year, heating zone 5. Heat calculation yields a 14K BTU requirement, Manual J close to 24K BTU. Currently with an 80k BTU...
View ArticleWayne Conversion Burner - Direct fire ignition module problems?
Thanks in advance for your help! I have a Weil McLain oil Boiler with a Wayne HSG200 gas conversion burner in it. It has been giving me nuisance lockouts for a few months now, but it always started...
View ArticleHeating season over
The heating season is over, do I drain my steam boiler, run some rectorseal or surgemaster in boiler before draining, do I not need to drain water if not being used till next heating season? What do...
View ArticleNew zone with one vent
Hello everyone, I have central HVAC system. Bosch Gas furnace, 120,000 BTU, forced air, up-flow (Model: BGH96M120D5) with currently 2 zones ( 1st floor w 2 dampers and 2nd floor w 1 damper). Basement...
View ArticleRadiant floor with poly b replacement boiler
Hello, I want to replace my boiler for my roughly 200sq foot radiant floor heating. The floor has poly b piping with brass fitting from what I can see. I'll attach info on my current boiler. I...
View ArticleNew Furnace sparking - blue lights when it operates
My daughter in Portland OR rents a home. the landlord replaced the furnace 4 months ago. When it operates, there are ticking noises and when looking into the air intake, you can see blue sparking. It...
View ArticleFrom letters to the editor @ the WSJ
Mr. Lieberman has some worthwhile gripes about washers that take forever to wash poorly, but he struck out in his complaints about gas-furnace regulations. Regulators are trying to encourage the...
View ArticleBurner Flame Mystery
Try this. On any fossil fuel flame, whether on a water heater, or a boiler or a furnace, remove the sheet metal so the flame is open to the room, lean close to the opening, and clap your hands in front...
View ArticleNti ftvn 101 error code
How do I clear nti ftvn 101 error code ? Pressure is at 20 and I’m pretty sure the other things mentioned in manual for this code are as they should be.
View ArticleCoil Replacement
AO Smith boiler coil replacement. Looking for a company to manufacture direct fire copper heat ex-changers. Water is non-potable as it is for a hydronic system. AO Smith tech support is lost and has...
View ArticleBurnham Alpine 210 stops heating water but thinks it's hot
I bought a new construction home in NH in Oct 2014 that has a Burnham Alpine 210 boiler in basement using Propane and FHA. House is about 4000 sq.ft. has 5 zones, 2 on 1st floor, 3 on second floor,...
View ArticleCrystal Ball prediction 15% Consumer drop
Actually not even close for all the increases the past 3 years but seeing a December rate decrease of 15% is encouraging
View Article