Quantcast
Channel: Gas Heating — Heating Help: The Wall
Browsing all 2112 articles
Browse latest View live

Image may be NSFW.
Clik here to view.

Viessman Part

I have a Vitodens 200 system, and I cannot find the part I need in the diagram... unless that means I have to buy an entire radial fan unit. Under the radial fan (Part #40) there is a flap that acts as...

View Article


Pex heating with tile

Hi, I am removing my old carpet and want to install tile down. Under the carpet I do have linoleum under the carpet which I will also be removing. My plan is to install pex tubing for the heating under...

View Article


Antique gas range help

I know this isn’t the proper forum, but it’s the same principles and I can’t find help anywhere else:Our ministry uses an antique (1940’s) Wolf double commercial oven and range (propane). Both ovens...

View Article

tekmar

slant fin caravan boilers (3) with Tekmar control and high limit switches keep tripping however temp of boilers are not at that limit

View Article

Miller CMF80 furnace runs for 45 seconds but will not fire

Hey guys. I have A Miller cmf80 Natural Gas Furnace in my mobile home. The induction fan will kick on for about 45 seconds but will not fire. I tapped on the gas valve and it fired. I have now replaced...

View Article


Flexible PVC pipe was used for venting a High Efficiency Gas Furnace - Water...

While the High Efficiency Gas Furnace is being used a water spot forms at the base of the Flue chimney where the Flexible PVC pipe vents to the roof. There is not a stainless steel liner in the...

View Article

Embassy Onex Domestic Hot Water Exchanger

Dear Team, I have a 2012 Embassy Onex 160 C condensing boiler. I'm seeing very light amount of droplets coming from the Domestic Hot Water Exchanger. Not sure if its the exchanger leaking or the 4...

View Article

Cat IV Venting

Most new category IV gas furnaces are dual-rated for either a direct-vent or a non-direct-vent installation. When installing with a direct-vent configuration, the intake and exhaust pipes are supposed...

View Article


Steam leak

I have a 8 year old Crown boiler for a one pipe steam. I have been losing approx a gallon of water every 4 days and the water level in the sight gauge drops a lot while the boiler is heating. It used...

View Article


endurance EBP

i am getting heat in my baseboards when the room temp is above thermostat set point. i replaced the flow check valve on the boiler input side but still same problem. is there an internal problem...

View Article

Boiler question

There’s a gas boiler in this apartment and recently an inspector came to check the boiler. I overheard him telling maintenance that the boiler is leaking so he shut the boiler completely down but the...

View Article

Navien NCB 240H - Any thoughts?

Hi everyone, A long while ago I had the NPE 240A installed. It's handled my hot water needs quite well, considering I'm in a situation where there are 3 bathrooms, 2 dishwashers and 2 washing machines....

View Article

Image may be NSFW.
Clik here to view.

Run pipes behind boiler

Hi, I have an old traditional gas boiler (two pipe, fully pumped system, if that matters) sitting on the floor and touching the wall, as from the first pic. The second pic zooms in on a hole the boiler...

View Article


Image may be NSFW.
Clik here to view.

Help with Info on this Ancient Bryant NoToil

Hi all. I'm wondering if there are any heating archeologists out there who can help me with any information on this Bryant NoToil. I've done the Google/internet searching to the maximum (that's how I...

View Article

Venting Issue- Gas Steam Boiler

I recently had an energy audit completed on my home (2 family, built 1931). As part of the audit, the venting for our water heaters and boilers was checked. We have 2 gas fired water heaters (2017 and...

View Article


Image may be NSFW.
Clik here to view.

Non-condensing vs. condensing boiler operation costs...

The TriAngle Tube non-condensing combi-boiler had been replaced last September with Viessmann 222-F, B2TB combi-condensing boiler. In our digital age, where every data is collected and made available...

View Article

Image may be NSFW.
Clik here to view.

Control board LED not coming on

Hello all, I recently installed some ecobees in my home and I had to replace the transformer in my Argo control board in the process. As of now the ecobees all have power, they all seem to call for...

View Article


Newbie chimney questions

Hi all, The home I purchased recently has a chimney that's in poor condition above the roof line. It's being used to exhaust the gas boiler (recent model LoganoUS/CA GC 144II) and Rheem gas water...

View Article

3/8 inch pex ball valves brass and plastic?

veiga makes some great plastic 3/8" valves for quickie lavatory applications, e.g. https://www.supplyhouse.com/Viega-43002-3-8-PureFlow-PolyAlloy-PEX-Crimp-x-1-2-Closet-Stop-Valve-Plastic-Nut but...

View Article

Image may be NSFW.
Clik here to view.

how far up are radiator legs solid? (gotta make a height adjustment)

when i took this pic of an American Arco Radiator, I though it was obvious but about 2 and half inches up the leg the casting flares and i'm thinking that is indicative of where one might begin to...

View Article
Browsing all 2112 articles