Navien 240e NG Recirc Pumps

$
0
0
Two weeks ago we had our house converted from oil heat to gas. Since then, the house has not been able to keep warm. Originally, using the outside thermometer to set the naviens heat curve, the house would never get above 60. The plumber argued all day that the problem was our house, our plumbing. Of course my counter argument was that the "less efficient" heating system was heating out house just fine at the same outdoor temperatures of (at that time) 0-15F. Anyway, eventually I ended up calling navian and they said to disable the temp sensor and crank the heat setting up to 194 (max). Before doing that I had to replace the sched 40 exhaust pipe to sched 80 to support the higher output temps. It worked, sort of. The house is warm(er). Now, it's -1F outside, and our house is at 63-64. The boiler is working full time, literally 24/7 to achieve this. Can't wait to get my first gas bill.

My previous oil boiler baseboard heating system consisted of three Taco 007-F5 pumps. These pumps have a max output of 25gpm according to the data sheet. The pumps the plumber chose to replace them with, when designing the new NG gas boiler system are Taco 007e-2F2 which have a max output of 16gpm. Today when I got home from working in NY, my wife was complaining about the temps again. I've sort of had it at this point. I'd rather have the more expensive and less efficient system at this point. Of course, I had to do more investigation, because the house cooled down since I left on Wednesday. 4-6 degrees in fact. Needless to say, the pump differences jumped out at me.

Do you guys think this is the actual source of the newfound heating problems? If so, what can I replace the new pumps with, that would be a direct swap at the higher flow rate?

Viewing all articles
Browse latest Browse all 2112

Trending Articles