Beacon/Morris Model BRU-75. SN K05590385002059. Propane Ceiling Unit Heater Garage. Uses a Honeywell SV9540M2229 Smart Valve.
Propane tank at 35%, waiting for fill.
When turning on, the Hot Surface Ignitor works, the Pilot light comes on, a large blue flame, but apparently no main gas is released at the "manifolds", so eventually the HSI stops , the Pilot light goes out and the Fan starts....there are six green flashes on the SmartValve.
Any thoughts on this will be greatly appreciated.
MichiganMike . . Battle Creek, MI.
↧