Gas line to outbuilding - sizing questions

$
0
0
I posted on another website and the recommendation was for a 1" line, but when I called the local HVAC place (without sizing anything) the guy I talked with said to go with 1-1/4" pipe. This is my situation: Maximum 150' run (after everything is installed, probably 130'), 1" SDR-11. 7" WC at meter 1" meter outlet Meter rated for 400K BTU Currently using 130K BTU total - water heater & furnace I want to provide a gas line for a boiler - Viessmann B1HA 26 in an outbuilding for radiant heating. Boiler is rated up to 94K BTU. When I look at charts for SDR-11 sizing, 1" appears to be sufficient... but 1 1/4" provides a significant increase of capacity so I'm leaning towards installing the larger pipe. However... The meter has just a 1" outlet - to use a 1-1/4" pipe, will I have to increase the meter size? Would I be better off requesting a pressure increase and adding regulators at the house and outbuilding? I'll be installing the gas line - pulling a mechanical permit - and will have an HVAC company connect the line once approved.