How many of you guys have had issues firing a boiler on propane? I was in a veisemann class and the instructor asked how much trouble we’ve had with propane. The class full of seasoned heating guys had no issues including me. Not three weeks later I was having issues. Figured it must be a fuel problem. I rigged a 5 gallon cylinder with an adjustable regulator and my manometer to verify my water column. It took two days to beat it into my Coustmer and the propane company they had 800 gallons of bad gas delivered. That was 12/18 this last November same problem didn’t see decals on the tanks so I asked the homeowners who was the gas company... Same company so I told them I would do the same thing prove it was bad gas not bad equipment. Go it to fire up first try with my small cylinder. They yanked the tanks set two new tanks filled them after I purged the bad gas had it up and running like a dream. So if your having ignition troubles I’d say go this route before replacing parts or trying to choke the unit down.
↧